Risk Assessment
Rule | Severity | Likelihood | Detectable | RepairableRemediation Cost | Priority | Level |
---|---|---|---|---|---|---|
SIG02-C | High | Probable | No | NoMedium | P12P6 | L1L2 |
Automated Detection
Tool | Version | Checker | Description | ||||||
---|---|---|---|---|---|---|---|---|---|
CodeSonar |
| BADFUNC.SIGNAL | Use of signal | ||||||
LDRA tool suite |
| 44 S | Enhanced Enforcement | ||||||
Parasoft C/C++test |
| CERT_C-SIG02-a | The signal handling facilities of <signal.h> shall not be used | ||||||
PC-lint Plus |
| 586 | Assistance provided: reports use of the signal function |
...