The risk in using in-band error indicators is difficult to quantify and is consequently given as low. However, if the use of in-band error indicators results in programmers' failing to check status codes or incorrectly checking them, the consequences can be more severe.
| Recommendation | Severity | Likelihood | Remediation Cost | Priority | Level | 
|---|---|---|---|---|---|
| ERR02-C | Low | Unlikely | High | P1 | L3 | 
Automated Detection
| Tool | Version | Checker | Description | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Parasoft C/C++test | 
 | CERT_C-ERR02-a | The Standard Library input/output functions shall not be used | 
Related Vulnerabilities
Search for vulnerabilities resulting from the violation of this rule on the CERT website.
Related Guidelines
Bibliography
| [Burch 2006] | 
| [ISO/IEC 9899:2011] | Subclause 6.3.2, "Other Operands" | 
...
...