Using a semicolon at the end of a macro definition can result in the change of program control flow and thus unintended program behavior.
Recommendation | Severity | Likelihood |
|---|
Detectable | Repairable | Priority | Level |
|---|---|---|---|
PRE11-C | Medium | Probable | Yes |
No |
P8 |
L2 |
Automated Detection
| Tool | Version | Checker | Description | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Astrée |
| macro-final-semicolon | Fully checked | ||||||
| Axivion Bauhaus Suite |
| CertC-PRE11 | |||||||
| CodeSonar |
| LANG.PREPROC.MACROEND | Macro Does Not End With ) or } | ||||||
| Cppcheck Premium |
| premium-cert-pre11-c | |||||||
| Helix QAC |
| C3412 | |||||||
| LDRA tool suite |
| 79 S | Enhanced Enforcement |
| PC- |
| lint Plus |
|
| 823 | Fully supported | |||||||
| Polyspace Bug Finder |
| CERT C: Rec. PRE11-C | Checks for macros terminated with semicolons (rule fully covered) | ||||||
| RuleChecker |
| macro-final-semicolon | Fully checked |
Related Vulnerabilities
Search for vulnerabilities resulting from the violation of this rule on the CERT website.
Related Guidelines
...
...